Home > Online water quality electrode > online blue and green algae detector
Products
  • Water Quality Sensor
  • Water Quality Testing
  • Online water quality electrode
  • Buoy Shore Station Series
  • online blue and green algae detector

    Blue and green algae sensor uses the characteristics of absorption peak and emission peak in the spectrum to emit a specific wavelength of monochromatic light into the water, the blue and green algae in the water absorb the energy of the monochrome light, release another wavelength of monochrome light, the light intensity emitted by the blue and green algae is proportional to the content of blue and green algae in the water.

    measuring principle

    Blue and green algae sensor uses the characteristics of absorption peak and emission peak in the spectrum to emit a specific wavelength of monochromatic light into the water, the blue and green algae in the water absorb the energy of the monochrome light, release another wavelength of monochrome light, the light intensity emitted by the blue and green algae is proportional to the content of blue and green algae in the water.

     

    functional characteristics

    The target parameters measured based on the fluorescence of pigment can be identified before the potential bloom is affected;

    No extraction or other treatment, rapid detection, to avoid the impact caused by the shelving of water samples;

    Digital sensor, strong anti-interference ability, the transmission distance is long;

    Standard digital signal output, which can be integrated and networked with other devices without a transmitter;

    Sensor site installation is convenient and fast, to achieve plug and play;

    Simple use, reliable results, interface operation instructions can reduce operation errors;

    Set up a visual alarm system to provide important alarm functions;

    The controller can realize the wall hanging mounting / panel installation / clip pipe installation;

    Sensor power supply positive and negative electrode reverse connection protection;

    Sensor RS485 A / B terminal with wrong power protection.

     

    Typical application

    Online monitoring of blue and green algae in water plant imports, drinking water sources and aquaculture;

    Online monitoring of blue-green algae in different water bodies, such as surface water and landscape water.

    Sensing technical parameter
    measuring range 200-300,000cells/mL(Customizable)
    measurement accuracyThe signal level of 1ppb Rhodamine dye corresponds to the value ± 10%
    repeatability±3%
    resolution ratio20cells/mL
    pressure limit≤0.4Mpa
    calibrationDeviation calibration, slope calibration
    requirementsThe distribution of chlorophyll in water is very uneven, so multi-point monitoring is recommended. The turbidity of the water is less than 50MTU
    Sensor materialBody: SUS316L+PVC,
    Upper and lower cover: POM, cable: PUR
    storage temperature-15° C to 50 ° C
    working temperature0 to 45 ° C (no freezing)
    sizeDiameter 30mm* Length 223mm
    weight0.55KG
    level of protectionIP68/EMA6P
    cable lengthStandard cable length: 10m, extendable 100m

    Controller parameters

    ModelMDS-KP500
    Display4.3 inches, 480*800 resolution, 262K color, IPS screen, wide viewing Angle, with backlight

    Capacitive touch screen with three protection processes (moisture-proof, mildew proof, salt spray proof)
    Display size95.0mm*53.9mm
    Measuring range-99999.0000~99999.0000
    Password ProtectionThe default password is 0000
    Compatible sensorDigital sensor
    Mounting methodDisk mounting (with chassis), wall-mounted mounting
    Alarm relay2 relays can set high and low alarm
    Current output2 isolated 4-20mA, maximum load 750Q, can be set
    Communication portRS485 Modbus RTU
    Memory backupAll user Settings are stored indefinitely in EERPOM
    historical dataThe storage capacity of 8000 points is recorded at a 5-minute interval
    Operating environment-10~+50℃,0~95% relative humidity, no condensation
    Storage environment-20 to +70 ° C,0 to 95% relative humidity, non-condensing
    The power supply12V±10%
    Power consumption of the instrumentless than 6W
    Instrument size144X145X85(mm)
    Protection classIP65





    WeChat MADSUR