Home > News > Maintaining an Idle Hexavalent Chromium Analyzer
Related News
  • Three methods of COD water quality detector
  • Overview and Performance of Online Turbidity Detector
  • Usage of Online COD Detector
  • Characteristics and Applications of Online COD Water Quality Detector
  • What is COD standard solution
  • How to detect COD content in water quality
  • Versatile Applications of Online Multi-Parameter Analyzers Across Industries
  • How Online COD detector Become Summer Unsung Water Quality Heroes
  • How Online Conductivity Detectors Deliver Unseen Value in Modern Industry
  • Why Testing BOD in Wastewater Matters?
  • Maintaining an Idle Hexavalent Chromium Analyzer

    Time:June 23, 2026

    Laboratory hexavalent chromium analyzers, if left unused for extended periods, can suffer from performance degradation in their optical components, electronic circuits, and sensors. Proper maintenance during idle periods is essential to preserve measurement accuracy and extend the instrument’s service life. The maintenance strategy should focus on four key areas: cleaning, component protection, environmental control, and periodic inspection.

    Cleaning Before Storage

    Before placing the analyzer into long-term storage, a thorough cleaning is necessary to remove residual reagents and sample residues that could corrode or contaminate sensitive parts. Detachable components such as the detection cell, cuvettes, sampling lines, and sensor probes should be dismantled and washed with appropriate cleaning agents and soft cloths. For stubborn contamination, ultrasonic cleaning may be employed. 

    After cleaning, all parts must be rinsed with deionised water, wiped with anhydrous ethanol, and completely dried to prevent mould growth. The optical components, including lenses and filters, should be gently wiped with specialised lens paper. Reagent lines should be emptied, rinsed with pure water, and dried to prevent crystallization and clogging.

    Protective Storage of Core Components

    Different components require specific storage conditions. Cleaned and dried optical parts, such as cuvettes and detection cells, should be placed in sealed boxes with desiccant to protect against moisture. Optical lenses and filters must be stored in a dark place, wrapped in light-shielding material or placed in opaque containers. Sensor probes should be coated with a protective agent and fitted with protective caps.

    For electrode-type sensors, they must be immersed in their designated storage solution and sealed. The solution level should be checked periodically to prevent drying out. All reagents should be removed from the instrument and stored separately according to their individual requirements, such as refrigeration or light protection.

    Environmental Control

    The storage environment plays a critical role in maintaining instrument integrity. The analyzer should be kept in a temperature-controlled, dry room, shielded from direct sunlight and heat sources. High humidity should be avoided through the use of dehumidifiers or sufficient desiccant. The storage area must be clean, free from dust, corrosive gases, and vibration. Placing the instrument on a stable bench and covering it with a dust cover provides additional protection.

    Periodic Inspection During Idle Periods

    Even when not in use, regular inspections are vital. A monthly check should confirm that dust covers and desiccant are functioning properly and that optical components show no signs of mould or oxidation. A more thorough inspection is recommended quarterly, including powering on the instrument to test circuits, warming up the system, and verifying alarm functions. The condition of sensor protection fluids and probe performance should also be assessed. Recording each inspection in a maintenance log helps track the instrument’s condition over time.



    Previous: Why Total Nitrogen Sometimes Reads Lower Than Ammonia Nitrogen in Water Testing
    Next: Ammonia Nitrogen Standards in Aquaculture



    WeChat MADSUR
    All rights reserved © 2025 Copyright MADSUR